ir Embedded Autosmart

The ir Autosmart calibration system is a system to calibrate, manage, analyze and visualize Exergen or other infrared sensors in connection with the Autosmart electronics over a freely definable measuring range. The special thing about it is that the fully automatic calibration of the infrared sensors can also be carried out directly at the destination of the sensor - i.e. on the system. The connection of the Autosmart electronics and a freely selectable IR sensor results in a high-precision, calibratable infrared sensor. All imaginable parameters can be set. You can choose between different interfaces, both analog and digital. 

The Autosmart electronics are available as a transmitter and as a USB version:
- USB
- Current output (0… 20mA or 4 ... 20mA)
- Voltage output (0… 10V, 0… 5V, 0… 2.5V or 0… 1V)

The ir Embedded Autosmart - Pro System consists of:

  • Black body
  • Autosmart-TC24-USB   - electronics as USB version
  • Autosmart-TC24-TR     - Electronics as a transmitter
  • IR-Calibration Reference             
  • ir reference probe type-K400
  • USB – Hub
  • Exergen sensor (Micro irt / c)
  • Melcom adapter 
  • Melcom adapter cable 2m

Commercially available sensors are fully calibrated upon purchase, can only be adjusted to a limited extent and cannot be calibrated.

Disadvantage: the thermal influences on the sensor caused by the system are not taken into account at the time of production and thus lead to poorer measurement results. The special thing about the ir Embedded Autosmart calibration system is that the infrared sensors can be calibrated directly at the destination, which means that negative influences on the system are largely calibrated out, and the infrared sensor is thus given a significantly higher measurement accuracy.



Typical areas of application:

Typical areas of application:

  • Heavy industry
  • Textile monitoring
  • Automotive industry
  • Melting processes
  • Laboratory tests
  • ISO 9000 for systems
  • Server room monitoring
  • Air and drying systems
  • food industry
  • environmental engineering
  • Packaging industry
  • Weather stations
  • Greenhouses

Excel
Display
Autosmart
Autosmart

Calibration system versions

The ir Embedded Autosmart calibration systems are available in 4 versions.

  • Autosmart-Cal-USB300             - USB version can be calibrated up to 300 ° C
  • Autosmart-Cal-TR300                - transmitter version can be calibrated up to 300 ° C
  • Autosmart-Cal-Pro1200             - transmitter and USB can be calibrated up to 1200 ° C
  • Autosmart-Cal-Ulitmate             - transmitter and USB can be calibrated up to a maximum of approx. 1800 ° C

Particularities:

Particularities:

  • With the Ultimate System, temperature can be calibrated indefinitely
  • Theoretically calibratable to - from -270 ... + 1820 ° C
  • Measuring range freely adjustable - from -270 ... + 1820 ° C
  • Calibration takes place fully automatically
  • The scale adjusts itself automatically.
  • Calibration can be transferred to other car smart sensors of the same design
  • Transfer measurements to Excel spreadsheet in real time
  • Calibrations on the system possible
  • Reference interchangeable in all versions
  • Automatic calibration of the reference
  • Miniature construction
  • Modular
  • High speed
  • Data logger, monitoring and logging software
  • USB 2.0 interface via Melcom adapter
  • Voltage output (0… 10V, 0… 5V, 0… 2.5V or 0… 1V)
  • Current output (0 ... 20mA or 4 ... 20mA)
  • Operating system: W10
  • Replaceable probe (Exergen - typical)